Furnace Not Heating in Austin: What to Check When the Heat Quits During a Freeze

Updated September 12, 2026 · Austin · Free quote matching, not a contractor

A furnace that won't heat in Austin is usually a dirty flame sensor, a failed hot-surface igniter, a thermostat or filter problem, or, on a heat pump, auxiliary heat strips that never kicked in. Central Texas cold snaps are short but severe, and the 2021 Winter Storm Uri and the 2023 ice storm showed how fast a house drops below 50°F when heat quits during a rolling outage. Start with the thermostat in HEAT mode, a fresh filter, the furnace power switch and breaker, and the gas supply if you have gas. Common freeze-week repairs typically run $150 to $500, more after hours. If you smell gas, leave the house and call Texas Gas Service first, then a licensed contractor.

Get free furnace repair quotesAbout 60 seconds. Checked local pros only.

Gas furnace or heat pump: figure out which you have first

Most Austin homes built before the mid-2000s and most homes with Texas Gas Service have a gas furnace in the attic or a closet. Newer subdivisions in Kyle, Buda, Leander, and Pflugerville, plus all-electric homes, often have a heat pump, which is the outdoor AC unit running in reverse with electric strips as backup.

Gas furnace checks: thermostat in HEAT, filter fresh, the light switch on the furnace cabinet ON, breaker not tripped, and the gas valve handle in line with the pipe. Listen for the sequence: inducer fan, clicking, ignition, then the blower. Where it stops tells the tech where to look.

Heat pump checks: on a freezing morning the outdoor unit may steam or stop for a defrost cycle, which is normal. Air from the vents that feels cool but not cold usually means the auxiliary strips are not engaging, often a thermostat setting, a tripped strip breaker, or a failed sequencer. Set the thermostat to EMERGENCY HEAT as a stopgap.

The parts that fail during Central Texas cold snaps

Flame sensor. A furnace that lights, runs a few seconds, and shuts off has a flame sensor coated in oxidation from sitting idle through nine warm months. It is the most common winter call in Austin and one of the cheapest fixes.

Igniter and pressure switch. A hot-surface igniter cracks after years of thermal cycling, and a pressure switch can fail when a flue is blocked or a condensate trap freezes. Both stop the ignition sequence before any flame.

Filters and airflow. Cedar pollen season peaks in December through February, exactly when the furnace runs. A clogged filter overheats the heat exchanger and trips the high-limit switch, so the blower runs but the burners cycle off. Replace the filter before assuming a part has failed.

Rolling outages, safety, and when to call

After a rolling outage or a grid event like Uri or the 2023 ice storm, many furnaces need only a reset: cycle the furnace switch off for 30 seconds, then on. Heat pumps may need the outdoor breaker cycled too. Do not run a generator, grill, or camp stove indoors under any circumstances.

Call a licensed contractor when the ignition sequence stops at the same point every time, when the breaker trips repeatedly, or when a heat pump runs but the house keeps losing ground. During a freeze, contractors triage no-heat calls; mention infants, elderly residents, or medical needs in the home.

LocalFixQuotes is a free matching service and not a contractor. We connect Austin homeowners with independent, TDLR-licensed HVAC contractors who diagnose furnace and heat pump problems and quote the repair. There is no obligation to hire.

Next step

Get furnace repair quotes from checked Austin HVAC contractors

LocalFixQuotes matches you with up to 4 independent local HVAC contractors. Free for homeowners, no obligation, and we don't perform the work ourselves.

Get my free quotes

FAQ

Questions Austin homeowners ask

Why is my furnace blowing cold air in Austin?

Most often the burners are not lighting, from a dirty flame sensor, a failed igniter, or a tripped high-limit switch caused by a clogged filter. On a heat pump, cool air usually means the auxiliary strips are not engaging.

How much does furnace repair cost in Austin?

Common winter repairs like flame sensors, igniters, and pressure switches typically run $150 to $500 installed. Control boards and blower motors commonly run higher, and after-hours calls during a freeze add a premium.

Should I use emergency heat on my heat pump during a freeze?

Only as a stopgap. EMERGENCY HEAT runs the electric strips alone, which heats the house but costs several times more per hour. Switch back to normal heat once the system is checked.

My furnace stopped after a power outage. What do I do?

Cycle the furnace switch and breaker off for 30 seconds, then on, and confirm the thermostat has power. Many furnaces lock out after a power blip and simply need the reset.

What if I smell gas near my furnace?

Leave the house immediately without flipping switches, then call Texas Gas Service or 911 from outside. Do not go back in until the line is checked, and call a licensed HVAC contractor afterward.